 TOTAL POWER INT'L
MBU100 Series 1Watt Ultra Miniature High SIP DC/DC Converters with Single Output
Key Features l SMT Technology l Miniture Package l I / O Isolation 1000VDC l Efficiency Up To 80% l MTBF > 2,000,000 Hours l Low Cost
+Vo +Vin Bipolar Push-Pull Inverter -Vin -Vo
Mechanical Configuration
Pin Connections
0.45 (11.5)
Pin 1 2
0.40 (10.2)
Function -Input +Input -Output +Output
3 4
0.02 (0.5) 0.10 (2.54) 0.02 (0.5) 0.07 (1.80) 0.01 (0.25)
0.126 (3.2)
Physical Characteristics Case Size ( 5 & 12V Input) 11.5*6.1*10.2 mm 0.45*0.24*0.40 inches 11.5*7.1*10.2 mm 0.45*0.28*0.40 inches Non-Conductive Black Plastic 1.3g( 5 & 12V Input ) 1.7g( 24V Input )
1
2
3
4
T
Case Size ( 24V Input) Case Material Weight
All dimensions typical in inches (mm). Tolerance= +/- 0.01 (+/- 0.25)
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -1-
TOTAL POWER INT'L MBU100
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter Input Surge Voltage ( 1000 mS ) Internal Power Dissipation 5VDC Input Models 12VDC Input Models 24VDC Input Models
Min. -0.7 -0.7 -0.7 ---
Max. 9 18 30 450
Unit. VDC VDC VDC mW
Environmental Specifications
Parameter Operating Temperature Storage Temperature Humidity Cooling Conditions Min. -25 -40 --Typ. ------Max. +75 +125 95 Unit ] ] %
Free-Air Convection
Model Selection Guide
Model Number Input voltage VDC MBU101 MBU102 MBU103 MBU104 MBU111 MBU112 MBU113 MBU114 MBU115 MBU116 MBU117 MBU118 24 (21.6 ~ 26.4) 12 (10.8 ~ 13.2) 5 (4.5 ~ 5.5) Output Voltage VDC 5 9 12 15 5 9 12 15 5 9 12 15 Output Current mA (Max.) 200 110 84 67 200 110 84 67 200 110 84 67 Output Current mA (Min.) 4 2 1.5 1 4 2 1.5 1 4 2 1.5 1 Input Current Max. Load mA (Typ.) 290 260 262 258 117 107 106 105 60 54 53 53 7 13 30 Input Current No Load mA (Typ.) Load Regulation % (Max.) 11 8 7 6 9 5 5 4 8 5 4 4 Efficiency % (Typ.) 69 76 77 78 71 77 79 80 70 76 79 79
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
Input Specifications
Parameter Input Voltage Range Reverse Polarity Input Current Input Filter Model 5V Input Models 12V Input Models 24V Input Models All Models Min. 4.5 10.8 21.6 --Typ. 5 12 24 --Max. 5.5 13.2 26.4 0.3 VDC A Unit
Internal Capacitor
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -2-
TOTAL POWER INT. MBU100
Output Specifications
Parameter Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Load Temperature Coefficient Output Short Circuit Over Line,Load & Temp. For Vin Change 1% Io=20% to 100% Conditions Min. ----------120 --Typ. {1.0 {1.2 100 ------{0.01 Max. {3.0 {1.5 150 200 5 --{0.02 Unit % % % mV P-P mV P-P mV rms. % %/]
See Model Selection Guide
0.5 Second Max.
General Specification
Parameter Rated Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500VDC 100KHz,1V Min. 1000 1000 --50 Typ. ----60 90 Max. ----100 110 Unit VDC M[ pF kHz
Input Fuse Selection Guide
5V Input Models 500mA Slow - Blow Type 12V Input Models 200mA Slow - Blow Type 24V Input Models 100mA Slow - Blow Type
Typical Applications
+ Fuse DC Power Source -
+Vin Single Output DC / DC Converter -Vin
+Out Load -Out
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -3-
TOTAL POWER INT'L MBU100
Derating Curve
5V Output Only
Output Power % 100 80 60 40 20 0 -25 -10 0 20 40 60
O
100 80 60 40 -3.3% / OC 20 0 80 C 100 125 Output Power %
Ambient Temperature
All Other Output
Output Power %
100 80 60 40 20 0 -25 -10 0 20 40 60
O
100 80 60 40 -4.0% / OC 20 0 80 C 100 125 Output Power %
Ambient Temperature
NOTE:
1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted. 2. Other input and output voltage may be available,Please contact factory. 3. Specifications subject to change without notice.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -4-


▲Up To Search▲   

 
Price & Availability of MBU114

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X